What it does
Returns the notice that carries an authority's reference, given alone or in a line copied from a letter (MHRA reference: 41295467, Rappel n° R2631739): an MHRA reference (41295467), an MHRA case reference (2026/010/009/601/195), an MHRA Device Safety Information reference (DSI/2026/013), an ANSM number (R2631739), an IGJ file number (fame-2611-00064) or page URL, or a Stockfoil id (uk:41295467). Call it when a letter, a ticket or a colleague quotes a number. found false means no notice published since coverage.publishedSince carries it, not that it does not exist. Spacing and dashes are forgiven (DSI 2026/013, FSN HME 2026 02 EN). A manufacturer's own FSN number (FSN-HME-2026-02-EN) is found only where MHRA prints it on its weekly page; otherwise it sits inside the letter, which Stockfoil does not read. BfArM references (48860/26) return source_not_served. Each result says how many notices in other countries it links to (call linked_notices for them) and, in relatedInCountry, which notices in its own country share a published reference with it: an MHRA original and its update, one IGJ file under two page dates.
Input
| Field | Type | Meaning |
|---|---|---|
reference required | string | The reference as printed by the authority, or a Stockfoil id. |
A real call
stockfoil notice_by_reference '{"reference":"R2631739"}'curl -X POST https://stockfoil.bulkhead.solutions/v1/tools/notice_by_reference \
-H 'content-type: application/json' \
-d '{"reference":"R2631739"}'{
"jsonrpc": "2.0",
"id": 1,
"method": "tools/call",
"params": {
"name": "notice_by_reference",
"arguments": {"reference": "R2631739"}
}
}Its real result
Data version 2026-11-09. Lists are cut to their first items here; the live answer carries all of them.
{
"dataVersion": "2026-11-09",
"coverage": {
"countries": ["FR"],
"publishedSince": "2026-08-01",
"notCovered": {"DE": "Germany (BfArM) is not served: ..."},
"note": "Notices published or updated by ANSM since 2026-08-01. No record here does not mean no notice exists: manufacturers send notices directly, and authorities publish late or not at all."
},
"query": {"reference": "R2631739"},
"sources": [
{
"country": "FR",
"authority": "ANSM",
"state": "ok",
"lastSuccess": "2026-11-09T21:53:25.335Z"
}
],
"attribution": [
"Source: ANSM, ansm.sante.fr, informations de sécurité. Titles and references reproduced unaltered; date of last update as stated on each record."
],
"warnings": [
"ANSM (FR) was last refreshed 2026-11-09, more than 3 days ago."
],
"notAdvice": "Metadata and links as the authorities publish them. Not medical, clinical or regulatory advice: the manufacturer's notice is the action channel, and the authority's page is the record.",
"found": true,
"notices": [
{
"id": "fr:R2631739",
"country": "FR",
"authority": "ANSM",
"kind": "field_safety_notice",
"title": "Biochimie – Bandelettes Test Strip 50CT Ket Strip Dual Pack, 20CT Ket Strip Nipro, 50CT Ket Strip Lifescan et 50CT Ket CA Statstrip – Nova Biomedical",
"manufacturer": "Nova Biomedical",
"device": "Bandelettes Test Strip 50CT Ket Strip Dual Pack, 20CT Ket Strip Nipro, 50CT Ket Strip Lifescan et 50CT Ket CA Statstrip",
"references": {"ansm": "R2631739"},
"noticeDate": null,
"publishedDate": "2026-11-06",
"updatedDate": "2026-11-06",
"url": "https://ansm.sante.fr/informations-de-securite/biochimie-bandelettes-test-strip-50ct-ket-strip-dual-pack-20ct-ket-strip-nipro-50ct-ket-strip-lifescan-et-50ct-ket-ca-statstrip-nova-biomedical",
"letterUrl": null,
"category": "RAPPEL DE PRODUIT",
"productType": "Dispositifs médicaux de diagnostic in vitro",
"authoritySummary": "Rappel n° R2631739 destiné aux pharmacies d'usage intérieur, officines et laboratoires d'analyses de biologie médicale",
"derived": {
"manufacturerKey": "nova biomedical",
"parsedFrom": "ANSM list title, split on its dashes"
},
"linkedCount": 3
}
]
}Every answer carries
dataVersionandcoverage: what Stockfoil holds and what it cannot see, Germany included.sources: each authority's refresh state, andwarningswhen a source is late or failing.attribution: the credit line each licence asks for. Keep it when you show the data.notAdvice: the manufacturer's notice is the instruction to act on.