1. Read the three registers every day
Stockfoil reads MHRA's field safety notice pages and Device Safety Information alerts through the GOV.UK content API, IGJ's notice pages through its sitemap, and ANSM's informations de sécurité list. Every fetch reads the site's robots.txt first and identifies itself honestly. Nothing is taken from Germany's BfArM, whose terms forbid reuse without consent, and no manufacturer's letter is ever fetched: letters are linked.
2. One record shape
Each notice becomes one record with the title exactly as the authority published it, the manufacturer and device, models, the authority's own references, and two dates kept apart: the date on the notice and the date the authority listed it. They differ by a median of 10 days at IGJ, and MHRA sometimes republishes older weekly pages. Anything Stockfoil parses is marked derived.
3. Read the manufacturer's name into a key
Accents and case are folded, legal forms (GmbH, B.V., SA, Inc) and places are dropped, and a search meets a name by its leading words. In the 477 notices published since 1 August 2026, 316 printed names fold to 254 manufacturers. There is no alias table: a parent and a subsidiary with another name stay apart.
4. Link across countries by one published rule
No authority prints another's number, so Stockfoil joins notices when the same manufacturer's distinctive device words meet within 120 days, and a consumable never links to an instrument. Today that gives 181 links and 85 device lines, 28 in all three countries. A link says same_device; whether two notices are one corrective action stays unknown, because only the manufacturer's FSCA number inside the letters could show it. When the rule does not fire, the answer is unknown, with the near misses and why each fell short.
5. Serve it to people and agents
Five read-only tools over a remote MCP server, a REST API and a CLI, with this site generated from the same answers. Every answer carries its data version, coverage, each source's state, the licence lines and the not-advice line.
What it will not do
- Give medical, clinical or regulatory advice, or tell anyone whether to use, remove or replace a device.
- Copy the manufacturers' letters, or IGJ's summaries taken from them.
- Guess that two companies are one, or that two notices are one action.
- Treat an empty answer as safe. No record here does not mean no notice exists: manufacturers send notices to their customers directly, and authorities publish late or not at all.
- Use a language model to produce any answer. The tools are deterministic code.
How it is checked
58 tests and 96 oracle checks, each written by hand against one of 50 authority pages, pass on every refresh; 87 end-to-end checks drive the five tools through MCP, REST and the CLI and require every surface to agree.