What it does
For one notice, says per other country whether a notice about the same device line was published there. No authority shares an identifier, so Stockfoil applies one fixed rule, returned in rules: same manufacturer, at most 120 days apart, distinctive device words in common, at least two and at least half of the shorter name (or the whole of one name), and no conflict in the kind of device (strips never link to a meter). Status same_device comes with the evidence (shared words, days apart, how the maker matched); it means the same maker's same device line was in a notice there, and sameAction stays unknown because only the letters carry the manufacturer's FSCA number. Status unknown means the rule did not fire: it lists up to ten same-maker notices that fell short, closest first, with the reason, the shared words and the days apart, and never claims they match or that the notice was not sent. sameCountry lists notices in the notice's own country that share a published reference with it. Call it after notices_since, search_notices or notice_by_reference with the id they return. It cannot see Germany, the manufacturer's letters or unpublished notices.
Input
| Field | Type | Meaning |
|---|---|---|
reference required | string | A Stockfoil id such as uk:41298418, or any reference notice_by_reference accepts. |
A real call
stockfoil linked_notices '{"reference":"uk:41048419"}'curl -X POST https://stockfoil.bulkhead.solutions/v1/tools/linked_notices \
-H 'content-type: application/json' \
-d '{"reference":"uk:41048419"}'{
"jsonrpc": "2.0",
"id": 1,
"method": "tools/call",
"params": {
"name": "linked_notices",
"arguments": {"reference": "uk:41048419"}
}
}Its real result
Data version 2026-11-09. Lists are cut to their first items here; the live answer carries all of them.
{
"dataVersion": "2026-11-09",
"coverage": {
"countries": ["UK", "NL", "FR"],
"publishedSince": "2026-08-01",
"notCovered": {"DE": "Germany (BfArM) is not served: ..."},
"note": "Notices published or updated by MHRA, IGJ, ANSM since 2026-08-01. No record here does not mean no notice exists: manufacturers send notices directly, and authorities publish late or not at all."
},
"query": {"reference": "uk:41048419"},
"rules": {
"version": "link-rules/2",
"windowDays": 120,
"text": ["6 sentences, in full in every answer"]
},
"sources": [
{
"country": "UK",
"authority": "MHRA",
"state": "ok",
"lastSuccess": "2026-11-09T21:53:25.335Z"
},
{
"country": "NL",
"authority": "IGJ",
"state": "ok",
"lastSuccess": "2026-11-09T21:53:25.335Z"
},
{
"country": "FR",
"authority": "ANSM",
"state": "ok",
"lastSuccess": "2026-11-09T21:53:25.335Z"
}
],
"attribution": [
"Contains public sector information licensed under the Open Government Licence v3.0 (MHRA, via GOV.UK).",
"Source: Inspectie Gezondheidszorg en Jeugd (IGJ), igj.nl, CC0.",
"Source: ANSM, ansm.sante.fr, informations de sécurité. Titles and references reproduced unaltered; date of last update as stated on each record."
],
"warnings": [
"MHRA (UK) was last refreshed 2026-11-09, more than 3 days ago.",
"IGJ (NL) was last refreshed 2026-11-09, more than 3 days ago.",
"ANSM (FR) was last refreshed 2026-11-09, more than 3 days ago."
],
"notAdvice": "Metadata and links as the authorities publish them. Not medical, clinical or regulatory advice: the manufacturer's notice is the action channel, and the authority's page is the record.",
"notice": {
"id": "uk:41048419",
"country": "UK",
"authority": "MHRA",
"kind": "field_safety_notice",
"title": "BioMérieux SA: EMAG®",
"manufacturer": "BioMérieux SA",
"device": "EMAG®",
"references": {"mhra": "41048419", "mhraCase": "2026/010/005/601/176"},
"noticeDate": {
"raw": "12th October 2026",
"iso": "2026-10-12",
"precision": "day"
},
"publishedDate": "2026-10-19",
"updatedDate": "2026-10-19",
"url": "https://www.gov.uk/drug-device-alerts/field-safety-notices-5-to-9-october-2026",
"letterUrl": "https://mhra-gov.filecamp.com/s/d/vJobz0rfPXCfsZtN",
"deviceTerm": "See comment section",
"derived": {
"manufacturerKey": "biomerieux",
"parsedFrom": "MHRA weekly page heading, split on its colon"
}
},
"countries": [
{
"country": "NL",
"authority": "IGJ",
"status": "same_device",
"sameAction": "unknown",
"meaning": "The link rule fired: same manufacturer, the same distinctive device words, no conflict in the kind of device, close in time. It does not prove the same corrective action, which only the manufacturer's FSCA reference inside the letters could show.",
"notices": [
{
"id": "nl:2026-11-02-biomerieux-sa-emag",
"country": "NL",
"authority": "IGJ",
"kind": "field_safety_notice",
"title": "bioMerieux SA EMAG",
"manufacturer": "bioMérieux SA",
"device": "EMAG",
"references": {"igjFile": "fame-2610-00195"},
"noticeDate": {"raw": "12-10-2026", "iso": "2026-10-12", "precision": "day"},
"publishedDate": "2026-11-02",
"updatedDate": "2026-11-02",
"url": "https://www.igj.nl/documenten/fsn-2026/11/02/biomerieux-sa-emag",
"letterUrl": "https://www.igj.nl/site/binaries/site-content/collections/documents/fsn-2026/11/02/biomerieux-sa-emag/fame-2610-00195-biom-rieux-sa-emag.pdf",
"derived": {
"manufacturerKey": "biomerieux",
"parsedFrom": "IGJ page labels Fabrikant and Product"
},
"linkEvidence": {
"manufacturer": "equal",
"daysApart": 0,
"sharedDeviceWords": ["emag"]
}
}
]
},
{
"country": "FR",
"authority": "ANSM",
"status": "same_device",
"sameAction": "unknown",
"meaning": "The link rule fired: same manufacturer, the same distinctive device words, no conflict in the kind of device, close in time. It does not prove the same corrective action, which only the manufacturer's FSCA reference inside the letters could show.",
"notices": [
{
"id": "fr:R2627732",
"country": "FR",
"authority": "ANSM",
"kind": "field_safety_notice",
"title": "Biologie moléculaire – automate Emag – Biomérieux",
"manufacturer": "Biomérieux",
"device": "automate Emag",
"references": {"ansm": "R2627732"},
"noticeDate": null,
"publishedDate": "2026-09-29",
"updatedDate": "2026-09-29",
"url": "https://ansm.sante.fr/informations-de-securite/biologie-moleculaire-automate-emag-biomerieux",
"letterUrl": null,
"category": "INFORMATION AUX UTILISATEURS",
"productType": "Dispositifs médicaux de diagnostic in vitro",
"authoritySummary": "Information n° R2627732 destinée aux laboratoires d'analyses de biologie médicale",
"derived": {
"manufacturerKey": "biomerieux",
"parsedFrom": "ANSM list title, split on its dashes"
},
"linkEvidence": {
"manufacturer": "equal",
"daysApart": 13,
"sharedDeviceWords": ["emag"]
}
}
]
}
],
"sameCountry": [],
"notCovered": {"DE": "Germany (BfArM) is not served: ..."}
}Every answer carries
dataVersionandcoverage: what Stockfoil holds and what it cannot see, Germany included.sources: each authority's refresh state, andwarningswhen a source is late or failing.attribution: the credit line each licence asks for. Keep it when you show the data.notAdvice: the manufacturer's notice is the instruction to act on.